Overhead crane knowledge – Richard Phillips, mechanical engineer, CP&A
The trolley wheel flange started grinding against a rail and wearing. This can be a symptom of wheel misalignment and/or rail misalignment.
-
This was caused by poor rail alignment. The rail gauge increased too much at... -
Richard Phillips. -
The trolley wheel flange started grinding against a rail and wearing. This... -
A gearbox input shaft failed because the alignment between the motor and... -
A gear mesh was not properly aligned. This caused uneven loading of the teeth... -
Limit switch and trigger alignment is crucial for proper function of the crane.